Transverse Magnetization
 
The xy component of the net magnetization vector at right angles to the main magnetic field. The precession of the transverse magnetization at the Larmor frequency is responsible for the detectable MRI signal. In the absence of externally applied RF energy, the transverse magnetization will decay to zero with a characteristic time constant of T2, or more strictly T2*.
spacer
 
• Related Searches:
    • Spin
    • Hahn Echo
    • Free Induction Decay
    • Coherent Gradient Echo
    • Longitudinal Magnetization
 
Further Reading:
  Basics:
Measuring T1 and T2 Relaxation - Introductory NMR & MRI from Magritek
   by www.azom.com    
MRI Resources 
Journals - Contrast Enhanced MRI - Examinations - Pediatric and Fetal MRI - NMR - Shielding
 
Tuning
 
The process of adjusting the transmitter and receiver circuitry so that it provides optimal signal performance at the Larmor frequency. A properly tuned scanner will produce images with a higher signal to noise ratio, and therefore improved diagnostic versatility.
More generally, tuning is the process of adjusting the components for optimal performance, including matching impedances.
spacer

• View the DATABASE results for 'Tuning' (5).Open this link in a new window

MRI Resources 
MRCP - Resources - Lung Imaging - Guidance - Equipment - Pacemaker
 
previous      26 - 27 (of 27)     
Result Pages : [1]  [2 3 4 5 6]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



MRI is trending to low field magnets :
reduced costs will lead to this change 
AI will close the gap to high field 
only in remote areas 
is only temporary 
never 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 28 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]